BEGIN:VCALENDAR
PRODID:-//University of Hawaii//UH Events Calendar//EN
VERSION:2.0
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Pacific/Honolulu
BEGIN:STANDARD
TZOFFSETFROM:-1000
TZOFFSETTO:-1000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
CLASS:PUBLIC
CREATED:20261118T235607Z
DESCRIPTION:Industry has used A36 steel for structural purposes to include buildings, bridges, and structural membrane\nfor tanks because of its material properties (tensile and yield strength), and its machinability and weldability.\nA36 is a mild, low carbon steel alloy that corrodes when mitigation is not in place and corrosion products can\noccupy up to five times the volumetric space. This unique characteristic of expansion can become\nproblematic when corrosion occurs in a crevice. For example, industry uses fillet-welded A36 patch plates as\nrepairs to existing material that produces a crevice. When corrosion occurs, the resulting expansion can\npropagate stress and plastic strains to the weld-plate interface and cause permanent deformation. This can\nundermine the structural and material integrity of the weld and plate system. The impact is investigated\nusing Finite Elemental Analysis (FEA) to validate and evaluate the corrosion effects on the weld and plate\nsystem for defect sizes of 1⁄4, 1⁄2, 1-, and 2- inch diameter holes and the effectiveness of Jotun 86, an\ninorganic zinc silicate corrosion inhibiting coating. This study utilizes data collected through experimental\ntesting through environmental exposure in the presence of corrosive chlorides, for 24 months, and lab\nexposure testing that replicates prolonged, accelerated periods of time for 300 cycles. A validation test and\nCOMSOL Solid Mechanics FEA was performed to find agreement between the model and the controlled\nexperiment. The model was refined and executed for the experimental plate configurations and the resulting\nFEA von Mises stress, equivalent plastic strain, and displacement plots were used to determine the effect of\ncrevice corrosion and the effectiveness of the use of a coating. COMSOL was also used to model and\nsimulate the patch plate as the resulting corrosion cell. COMSOL Corrosion Module modeled a thin, 10 μm,\nand thick, maximum displacement observed ~10 mils (≈254 μm), electrolyte film, and the impact of film\nthickness on the corrosion potential and current density of the plate and hole sizes were evaluated.
DTEND;TZID=Pacific/Honolulu:20260401T220000Z
DTSTAMP:20261118T235607Z
DTSTART;TZID=Pacific/Honolulu:20260401T200000Z
LAST-MODIFIED:20261118T235607Z
LOCATION:Zoom
PRIORITY:5
SEQUENCE:0
SUMMARY;LANGUAGE=en-us:ME PhD Thesis Defense- Sonya Ling
TRANSP:OPAQUE
UID:179508216745367web-support-l@lists.hawaii.edu
END:VEVENT
END:VCALENDAR
